CHRONO-LOG® Platelet Function Reagents

CHRONO-LOG PLatelet Function Reagents Provide High Accuracy and Low Costs Per Test

Chrono-log offers a complete line of highly concentrated platelet aggregation reagents, requiring only micro-portions per test. The standard aggregation reagents: Thrombin, ADP, Collagen, Ristocetin, Epinephrine and Arachidonic Acid are available, as well as CHRONO-LUME® and ATP Standard reagents for determination of dense granule release when performing Lumi Aggregation.

Please review this year-long study which confirmed the exceptional stability of Chrono-log aggregation reagents.

CHRONO-LOG® CHRONO-PAR® Reagents are validated for use in both Whole Blood and PRP samples.

ADP

CHRONO-LOG bottle of ADP

Collagen

CHRONO-LOG bottle of Collagen

Each vial contains 1mg of native Collagen fibrils (type I) from equine tendons suspended in isotonic glucose solution of pH 2.7. Performs 500 to 1000 tests in PRP or Whole Blood samples.

Ristocetin

CHRONO-LOG bottle of Ristocetin

Arachidonic Acid

CHRONO-LOG bottle of Arachidonic Acid

Epinephrine

CHRONO-LOG bottle of Epinephrine

Thrombin

CHRONO-LOG bottle of Thrombin

CHRONO-LUME® Reagents

For Performing Secretion Study Simultaneously with Aggregation

CHRONO-LOG bottle of ATP
CHRONO-LUME Reagent kit
Reagent for measurement of ATP release. Each vial contains 0.2 mg luciferin, 22,000 units d-luciferase plus magnesium sulfate, human serum albumin, stabilizers and buffer. Kit includes 4 vials of CHRONO- LUME plus a vial of lyophilized adenosine 5′ triphosphate for use as an ATP Standard. Performs 50 to 100 tests in PRP or Whole Blood samples.

Ristocetin CoFactor Assay

For the Quantitation of Ristocetin CoFactor Activity

Ristocetin CoFactor Assay Kit
(von Willebrand Factor Assay)

CHRONO-LOG Ristocetin CoFactor Assay Kit
For use in the quantitative determination of Factor VIII Ristocetin Cofactor Activity in citrated plasma. The following Materials included provide volumes sufficient to run 15 determinations: Ristocetin, 7.5 mg/vial; Lyophilized Human Platelets, 6 mL; von Willebrand Reference Plasma, Normal, 1.0 mL; von Willebrand Reference Plasma, Deficient, 0.5 mL; Tris Buffered Saline (TBA) 12 mL.

Lyophilized Human
Platelets

CHRONO-LOG bottle of Lyophilized Human Platelets

For use in the quantitative determination of Factor VIII Ristocetin Cofactor Activity in citrated plasma. Each vial provides 6 mL of Platelets following reconstitution with Tris Buffered Saline (TBS) for performing up to 15 determinations.

Ristocetin

CHRONO-LOG bottle of Ristocetin

vW Reference Plasma
Normal

CHRONO-LOG bottle of vW Reference Plasma Normal

vW Reference Plasma
Deficient

CHRONO-LOG bottle of vW Reference Plasma Deficient

All CHRONO-LOG® Platelet Function Reagents are FDA approved and CE marked and can be used for clinical and pharmaceutical studies.